"h | 10 -mm - | | b | 26 -mm - | | lmax | 4000 -mm - |  - | Maximum length L of guideway- longer guideways are supplied in several sections и are marked accordingly. |
|
|  - | 1) |  - | | a2 | 23 -mm - | | a6 | 13 -mm - | | aL max | 116 -mm - |  - | aL и aR are dependent on the guideway length L |
| aL min | 11 -mm - |  - | aL и aR are dependent on the guideway length L |
| aR max | 116 -mm - |  - | aL и aR are dependent on the guideway length L |
| aR min | 11 -mm - |  - | aL и aR are dependent on the guideway length L |
| dLW | 6 -mm - | | ez | 5 -mm - | | h1 | 3,5 -mm - | | h4 | 5 -mm - | | jL | 125 -mm - | | ly | 8681 -mm^4 - | | lz | 1897 -mm^4 - | | LFQ | 216 -mm^2 - |  - | Value for cross-sectional area |
| N1 | 6,5 -mm - |  - | For screws to DIN 912-8.8 (DIN EN ISO 4762), under maximum load support washers to DIN 433 (DIN EN ISO 4762) are required. |
| N3 | 12 -mm - | | Wy | 790 -mm^3 - | | Wz | 379 -mm^3 - | |
|  - | mS | 800 -g/m - | |  - |  - |  - | Ordering designation: - Guideways without holes: LFS..-OL - Guideways in design with anti-corrosion protection: LFS..-RB |
|  - |  - |  - | Modulus of elasticity for LFS..-CH, -CHE, -CHEE, -FH, -FHE, -FHEE: 72 000 N/mm2 |
|
| " |
|