mLaw | 2,2 -kg - | |
mtot | (Ltot - 56) x 0,0105 + 6,5 -kg - | |
do x Pz | 20 x 5 - |  - | Threaded spindle: do x Pz = nominal spindle diameter x spindle pitch |
|
M0x | 664 -Nm - |  - | Permissible static moment of carriage guidance system: The values are single loads и apply when the underside of the actuator is fully supported. These must be reduced for combined loads. For design criteria of the linear guidance system, see Catalogue PF1, Monorail Guidance Systems. |
|
M0y | 1000 -Nm - |  - | Permissible static moment of carriage guidance system: The values are single loads и apply when the underside of the actuator is fully supported. These must be reduced for combined loads. For design criteria of the linear guidance system, see Catalogue PF1, Monorail Guidance Systems. |
|
M0z | 1200 -Nm - |  - | Permissible static moment of carriage guidance system: The values are single loads и apply when the underside of the actuator is fully supported. These must be reduced for combined loads. For design criteria of the linear guidance system, see Catalogue PF1, Monorail Guidance Systems. |
|
Ca | 17,9 -kN - |  - | Spindle bearing arrangement: Values are valid only for calculating Lh. Basic axial load rating = for design criteria for the locating bearing, see Catalogue HR1, Rolling Bearings |
|
C0a | 28 -kN - |  - | Spindle bearing arrangement: Values are valid only for calculating Lh. Basic axial load rating = for design criteria for the locating bearing, see Catalogue HR1, Rolling Bearings |
|
ly | 281 -cm^4 - |  - | Geometrical moments of inertia of support rail |
|
lz | 219 -cm^4 - |  - | Geometrical moments of inertia of support rail |
|
C | 21,3 -kN - |  - | Basic load ratings of track roller guidance system Values are valid only for calculating Lh. |
|
C0 | 54 -kN - |  - | Basic load ratings of track roller guidance system Values are valid only for calculating Lh. |
|
 - | F/FM - |  - | Spindle nut: F = single nut FM = preloaded double nut |
|
CI | 10,5 -kN - |  - | Basic load ratings of spindle nut Values are valid only for calculating Lh. F = single nut FM = preloaded double nut
Basic load ratings C и C0 to DIN 69051. Due to the incorporated calculation algorithm, the C и C0 values may differ in comparison with earlier results to DIN 69051. |
|
C0 I | 16,6 -kN - |  - | Basic load ratings of spindle nut Values are valid only for calculating Lh. F = single nut FM = preloaded double nut
Basic load ratings C и C0 to DIN 69051. Due to the incorporated calculation algorithm, the C и C0 values may differ in comparison with earlier results to DIN 69051. |
|